Project Description
Roof Edge and Wall Base Flashing Repairs
Roof Edge Repair
- Cut back roof at edge metal on upper portion. 9′ x 9′ area.
- Furnished and installed new drip edge metal with a “sandwich” layer of smooth bitumen underneath.
- Spud perimeter tie in of repair area.
- Swept loose gravel from repair area.
- Furnished and installed inverted cap sheet over repair area and properly secured.
- Furnished and installed modified bitumen over repair area.
- Tied in new membrane to existing roof system.
- Furnished and installed 3 course at perimeter tie in.
- Spread swept gravel evenly over roof system.
- Removed and hauled away all debris generated by repair work.
- Cleaned and primed repair area.
Base Flashing Repair
- Swept loose gravel from repair area. 6′ x 12′ at wall base flashing.
- Cut back roof at wall turn up.
- Cleaned and primed repair area.
- Furnished and installed modified bitumen over repair area.
- Tied in new membrane to existing roof system.
- Removed and hauled away all debris generated by repair work.